contact us Chat online Phone Number

Marine gas detector

Date:2020-06-05  Click:343   Share to:



  • Name:marine gas detector 
    Explosion proof mark: ExibIIBT3 Gb 
    Certification: CCS 
    Executive standard: GD01-2006, GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010 
    Measuring range :0 ~ 100%LEL 
    Accuracy :+ 2%FS 
    The response time is less than 30 seconds 
    The recovery time less than 30 seconds 
    Set mode: code + key 
    Alarm set alarm: 10%FS 
    Alarm mode a relay passive contact output (A1 segment), contact capacity 1A 24VDC (optional) 
    Explosion proof mark ExibIIBT3 Gb 
    Explosion proof thread 3/4 "NPT/M20 
    Protection class IP66 
    Signal output 4 ~ 20mA standard current (line 3) 
    Maximum transmission distance :1000 m (3*1.5mm2 marine cable) 
    Operating temperature :-40 ℃ ~ +70 ℃ 
    Relative humidity: 0 ~ 95%RH 
    Power :24VDC + 8VDC 
    Maximum power consumption :2W 
    Weight : 1.7Kg 
    Color :yellow