Model:
Features:
1. Touch-tone fast digital control output voltage and frequency function, programmable dynamic output voltage,
Low voltage: 0 v to 150 v; High voltage 150 v to 300 v
2. Load voltage regulator rate: plus or minus 1%;
3. Original voltage frequency combination fast output function: 220 v/50 Hz and 110 v/60Hz and 120 v/60 Hz;
4. Output frequency range: 45 Hz - 70 Hz (400 Hz optional)
5. High precision LED display: voltage, current, frequency, active power;
6. High precision LED display: voltage, current, frequency, active power;
Main technical parameters:
Model (BP)
|
5005
|
5010
|
5020
|
5030
|
5040
|
5050
|
5060
|
55100
|
51500
|
Output capacity
|
500VA
|
1KVA
|
2KVA
|
3KVA
|
4KVA
|
5KVA
|
6KVA
|
10KVA
|
15KVA
|
Circuit way
|
IGBT/PWM pulse width modulation mode
|
Ac input
|
Single-phase 220 v/50 Hz, 60 Hz
|
AC output
|
phase
|
Single phase
|
voltage
|
low-grade
|
0V~150V
|
high-grade
|
0V~300V
|
Frequency
|
Fifty Hz and Hz, 45 ~ 70 Hz and 400 Hz (optional)
|
Maximum current
|
0V~150V
|
4.2A
|
8.4A
|
17A
|
25A
|
34A
|
42A
|
50A
|
84A
|
125A
|
0V~300V
|
2.1A
|
4.2A
|
8.4A
|
12.5A
|
17A
|
21A
|
25A
|
42A
|
63A
|
Frequency stability
|
≤0.1%
|
Load voltage regulator rate
|
±1%
|
Waveform distortion
|
≤2%(impedance load)
|
Reaction time
|
Maximum 2 ms
|
Instructions/resolution
|
LED digital display frequency, voltage, current, active power
|
Protection
|
Input without fuse switch, output without fuse switch,
electronic circuit quickly detect overvoltage, over current, overload,
high temperature and short circuit and automatic tripping protection and alarm device.
|
Cooling device
|
Forced fan cooling
|
Environment
|
Working temperature
|
0℃~40℃
|
Relative humidity
|
0 ~ 90% (not condensation state)
|
Size
width×high×depth (mm)
|
180 x 300 x 440
|
280 x450 x500
|
320 x 620 x 620
|
550 x 650 x 740
|
Model (BP)
|
5200
|
5250
|
5300
|
5450
|
5600
|
51000
|
51200
|
51500
|
52000
|
Output capacity
|
20KA
|
25KVA
|
30KVA
|
45KVA
|
60KVA
|
100KVA
|
120KVA
|
150KVA
|
200KVA
|
Circuit way
|
IGBT/PWM pulse width modulation mode
|
AC input
|
Three-phase 380 v/50 Hz, 60 Hz
|
AC output
|
phase
|
Single phase
|
voltage
|
low-grade
|
0V~150V
|
high-grade
|
0V~300V
|
Frequency
|
50Hz、60Hz、45~70Hz、400Hz
|
Maximum current
|
0V~150V
|
168A
|
208A
|
250A
|
375A
|
500A
|
834A
|
1000A
|
1250A
|
1667A
|
0V~300V
|
84A
|
104A
|
125A
|
188A
|
250A
|
417A
|
500A
|
625A
|
834A
|
Frequency stability
|
≤0.1%
|
Load voltage regulator rate
|
±1%
|
Waveform distortion
|
≤2%(impedance load)
|
Reaction time
|
Maximum 2 ms
|
Instruction/resolution
|
LED digital display frequency, voltage, current, active power
|
Protection
|
Input without fuse switch, output without fuse switch,
electronic circuit quickly detect overvoltage, over current, overload,
high temperature and short circuit and automatic tripping protection and alarm device.
|
Cooling device
|
Forced fan cooling
|
Environment
|
Working temperature
|
0℃~40℃
|
Relative humidity
|
0 ~ 90% (not condensation state)
|
Size
Width×high×depth (mm)
|
580 x 1060 x 820
|
700 x 1205 x 1205
|
800 x 1205 x 1450
|
1000 x 1450 x 1600
|
Note: according to the customer request custom specifications of power supply.
|