frenquency charger

Date:2020-06-17  Click:470   Share to:

  • frenquency charger


     

    Type 

    BOCHI 001

    Control method

    SPWM control method / voltage space vector mode  SPWM 

    Frequency setting resolution 

    Digital: 0.01 Hz (100 Hz less), 0.1 Hz (100 Hz or more)

    Analog: 0.05 Hz / 50 Hz, output frequency range: 0 - 400 Hz

    Frequency Accuracy

    Digital: 0.01% of maximum output frequency

    Analog: 0.1% of maximum output frequency

    V / F ratio

    Linear, can be set V / F curve

    Overload

    150% rated current -1 minute, 

    rated current 200% - 0.5 seconds. 

    (Inverse time characteristics) 

    Torque compensation 

    Manual torque compensation (0 - 30%)

     

     

     

     

     

    Operate 

    Input 

    Signal 

    Operational mode

    Keypad / Terminal / RS485 communication 

    Frequency setting 

    Analog: 0 - 10V / 0 ~ 5V,-10V ~ +10 V, 4 - 20 mA / 0-20 mA

    Digital: Keypad / RS485 communication

    Start signal 

    Forward, reverse 

    Multi-speed 

    You can set up to eight speed 

    (using the multi-function terminal)

    Deceleration time

    0-6000 seconds, acceleration and 

    deceleration time can be switched 

    Acceleration and 

    deceleration mode 

    linear, S-type 

    Jog 

    Slow Running

    Automatic operation

    Analog setting automatically start frequency 

    is higher than the lower limit

    Fault reset 

    When the protection function is active, 

    you can automatically reset the fault condition,

    you can set the number of fault recovery

    Output signal

    Operating status 

    Frequency detection level, overload alarm, 

    over voltage, under voltage, drive overheating, 

    run, stop, constant speed, automatic program run

    Fault output

    Contact output AC 250V 1A, DC 30V 1A

    OC gate output

    Multifunction output 

     

     

     

     

     

     

     

    Analog Output

     

    From the output frequency, set the frequency, 

    output current, output voltage selection 

    (output voltage: 0 - 10V, 0 ~ 20mA, 4 ~ 20mA) 

    Protection 

    Frequency changer protection  

    Constant over-current, over-current acceleration and 

    deceleration over-current, overvoltage constant speed, 

    acceleration, overvoltage, deceleration overvoltage, 

    module fault protection, under-voltage, over-temperature, 

    overload, external fault protection. 。

    Frequency changer alarm 

    Stall protection, overload alarm, temperature sensor failure.

    Momentary power 

    Less than 15 milliseconds: For continuous operation

    Greater than 15 milliseconds: Stop 

    Display 

    Keyboard

    Running Messages

    Set the frequency, output current, 

    output voltage, the bus voltage, 

    the input signal, the feedback value, 

    module temperature, the output frequency, 

    the motor synchronous speed.。

    Error Messages

    When fault protection when operating state, 

    the preservation of four fault history information. 

    Environment

    temperature

    -10 ℃ ~ 40 ℃

    Storage Temperature

    -20 ℃ ~ 65 ℃

    Humidity

    Maximum 90% RH. (No condensation)

    Height / vibration

    3,000 m the following, 5.9m / s ² (= 0.6g) less

    Application site

    No corrosive gas, flammable gas, oil mist or dust, and other

    Cooling 

    Forced air cooling